Skip to content

MDG

Overview

There is a MDG ATMe on the SR Fly Floor Perch with a AF 1 fan to distribute the haze across the stage.

Location

  • Position: SR Fly Floor Perch
  • Mounting: On the floor + AF 1 mounted on the hand rail.

Power & Control

  • Power source: SR Fly Floor
  • DMX source: SR FLy Floor
  • Cable type: TrueOne

Channels & Addressing

### Haze (MDG) - Channel: 901 - Fixture Type: ATMe CFT (custom) - Universe/Address: 10/263–265

### Haze Fan - Channel: 911 - Fixture Type: Generic Fan - Universe/Address: 10/266

Consumables:

  • MDG - Neutral Fluid 4 Litre (Mineral Oil Fog Fluid)
  • CO2 Gas Bottle

Fuild Top Up

Before checking fluid levels & topping up haze fluid power must be cut and gas must be turned off!

Images

Overview

Usage

Always it's haze duh

Troubleshooting

  • Fault: No haze output
  • Check: Is heating at 100%?
  • Check: Has the desk sent a power on command?
  • Check: Is there enough fuild in the tank?
  • Fault: Flashing screen
  • Check: Swap gas bottle
  • Fault: Heating Cycle complete but stuck on Haze Off
  • Try: purging then power cycling

Purging

Easiest way to force a purge is to put the unit on manual control mode then back to DMX mode